BOXER® Tankless Water Heater with 3 GPM Activation Flow Rate
BOXER® Tankless Water Heater with 3 GPM Activation Flow RateBOXER® Tankless Water Heater with 3 GPM Activation Flow Rate
Share this page

BOXER® Tankless Water Heater with 3 GPM Activation Flow Rate

Model Number:  ERB-L_3P Series
Chronomite - BOXER® - 3 Phase - Low Activation - L9 models are manufactured to provide reliable tepid water with flow rates from 3.0 gpm to 30.0 gpm. There is no pressure and temperature relief valve needed (unless required by code), saving time and money on installation.

Housing is fabricated from rugged stainless steel.
Element Assembly is fabricated from Celcon plastic.
Heating Coils are Nichrome.

Minimum Operating/Activation Flow Rate:  3 Gallons (11.4 liters) per Minute
Wattage: 68.4 to 154 Kilowatt Range (depending on model)
Product Function:
  • Typical Applications include Commercial and Industrial
  • Ideal for Eye/Face Drench Shower specified with 84°F tepid water to meet ANSI Z358.1 (Specify Option -F)
  • Unlimited hot water
  • Saves water and energy - 99% energy efficient
  • Meets applicable building codes including UL, UPC.
  • Environmentally friendly


Regularly Furnished:
  • Uses a digital microprocessor for temperature control 
    Ultra quick response times for temperature variations - 120 times per second. Microprocessor use is the most energy efficient means of heating water
  • Rugged stainless steel housing (Standard)
  • Overall Size: 26.75 W x 21 H x 7.5 D inches (67.9 x 53.3 x 19.1 cm)
  • Standard user adjustable temperature 70° to 125°F  (21.1° to 51.7 °C)
  • Other Factory preset single temperature may be requested between 90° to 160°F (32.2° to 71.1°C)
  • Made in the U.S.A.

Loading...
{{ promotion.promotionTypeName }}

{{ product.promotionCatchPhrase }}

Model Number: {{ product.modelNumber }}

{{ product.productName }}


View on {{ product.siteDisplayName }}
NameDescriptionFile Size
Manual ERB Series Water Heater (pdf)Manual ERB Water Heater (208-600v Three-Phase - including Low, Standard, High Activation Model)892 KBView

Options

  • De-ionized (-DI)
  • NEMA 4 Grey Finish Housing (-N4)
  • NEMA 4 Stainless Steel Finish Housing (-N4X)
Minimum Operating/Activation Flow Rate:  3 Gallons (11.4 liters) per Minute
ModelAmps/ Phase3 Ø VoltageTemp Rise @ 20 GPMTemp Rise @ 23 GPMTemp Rise @ 30 GPMWatts
ERB-360L/208_3P20820826 ° F22 ° F17 ° F75,000
ERB-360L/240_3P20824029 ° F26 ° F20 ° F86,000
ERB-180L/380_3P10438023 ° F20 ° F16 ° F68,400
ERB-270L/380_3P15638035 ° F30 ° F23 ° F102,600
ERB-360L/380_3P20838047 ° F41 ° F31 ° F136,800
ERB-180L/415_3P10441526 ° F22 ° F17 ° F74,700
ERB-270L/415_3P15641538 ° F33 ° F26 ° F112,100
ERB-360L/415_3P20841551 ° F44 ° F34 ° F149,400
ERB-160L/480_3P9348026 ° F23 ° F18 ° F77,000
ERB-240L/480_3P13948039 ° F34 ° F26 ° F115,000
ERB-320L/480_3P18548053 ° F46 ° F35 ° F154,000
ERB-128L/600_3P7460026 ° F23 ° F17 ° F77,000
ERB-192L/600_3P11160039 ° F34 ° F26 ° F115,000
ERB-256L/600_3P14860052 ° F46 ° F35 ° F154,000

Applications

  • Emergency Drench Shower